济南变频器维修:变频器可运用的制造行业十分普遍,办公环境也不同,巧遇连阴雨气温软启动器漏水了该怎么办呢:

Jinan Inverter Maintenance: Frequency converter can be used in the manufacturing industry is very common, the office environment is different, even when the rain and temperature soft starter leaks, how to do?

先打开变频器面板,将变频器内部用干毛巾或者纸巾擦干,再用电吹风冷风吹干显示器、PC板、推动板、功率元件、风扇等,最好用纯度%的酒精将以上元件擦洗一遍再用电吹风冷风吹干.过一小时左右后等干的差不多了再重新用酒精擦洗一次,再打开热风吹一遍

First open the converter panel, wipe the inside of the converter with a dry towel or paper towel, and then dry the display, PC board, driving board, power components, fans, etc. with a hairdryer cold air. It is best to wipe the above components with pure alcohol and then dry them with a hairdryer cold air. After about an hour, the dried parts are almost dried and then reuse alcohol. Scrub once, turn on the hot air and blow again

重点吹干处理底下元件:电位器、开关电源变压器、显示器、续电器、接触器、电抗器、风扇、电解电容、功率模块,必须低温档几次进行烘干,开关电源变压器、接触器、功率模块更是重中之重

Focus on drying the underlying components: potentiometers, switching power transformers, monitors, continuing appliances, contactors, reactors, fans, electrolytic capacitors, power modules, must be dried several times at low temperature, switching power transformers, contactors, power modules are the most important.

济南变频器维修

Maintenance of Jinan Inverter

有时模块可能看上去烘干了,原本内部仍有积水.在干涸的处境下安顿一平明再检查一下,有没出现返潮的地方,并将重点元件烘干一遍.烘干后首次通电必须一送就无妨断,看变频器回响处境

Sometimes the module may appear to be dried up, but there is still water in the original interior. In the dry situation, settle down and check again, there is no moisture back, and dry the key components once. After drying, the first power must be delivered without interruption, to see the frequency converter echo situation.

若无异常再送电常常就无妨正常为己所用了.原本仅有常常多提防防护,变频器进水时不是通电立体,变频器常常是不会坏的

If there is no abnormal re-transmission of electricity, it is often as good as normal for their own use. Originally, only often more guard against protection, the frequency converter when entering water is not electrified three-dimensional, the frequency converter is often not bad.

如果是通电立体发现进水,应在第一时间断电.如果未形成内部短路毁灭,无妨按上面方法进行抢救.如果有零件出现短路烧坏,最好找专业变频器维修工程师来检测维修

If the water is found in the electrified stereo, the power should be cut off at the first time. If there is no internal short-circuit destruction, it is better to rescue according to the above method. If there is a short-circuit burnout of the parts, it is better to find a professional frequency converter maintenance engineer to check and repair.http://www.bcabb.com/